Specifications
Conditions and Factors:
- 0°F outdoor ambient temperatures, two layers of insulated tarp
- Ground thaw – Heat transfer – 85 BTU’s/ft., 180°F ( 82°C) fluid “supply” temperatures
- Concrete cure – Heat transfer – 42 BTU’s/ft., 80°F ( 27°C) fluid “supply” temperatures
Central heating module thaw/cure specification estimate
Thaw Capabilities
Using system package “hose reel” only |
To match maximum BTU output (dependent on conditions & factors) |
||||||
Central Heating Module | Fuel Type | BTU Output | Total Hose Length (ft) | Thaw area @ 18″c/c (sq ft) | Total Hose Length (ft) | Hose Loops @750′ | Thaw area @ 18″c/c (sq ft) |
2100-0900 | d | 761,600 | 6,000 | 9,000 | 8,250 | 11 | 12,375 |
2100-0600 | d | 508,564 | 6,000 | 9,000 | 6,000 | 8 | 9,000 |
Cure Capabilities
Using system package “hose reel” only |
To match maximum BTU output (dependent on conditions & factors) |
||||||
Central Heating Module | Fuel Type | BTU Output | Total Hose Length (ft) |
Cure area @ 24″c/c (sq ft) |
Total Hose Lengths (ft) | Hose Loops @ 750′ |
Cure area @ 24″c/c (sq ft) |
2100-0900 | d | 761,600 | 6,000 | 12,000 | 16,500 | 22 | 33,000 |
2100-0600 | d | 508,564 | 6,000 | 12,000 | 12,000 | 16 | 24,000 |