Specifications
General
Weight
1,815 LBS. (823 KG)
Electrical
115/230 V, single phase, 60 Hz, 30 Amps
Loading - Standard
Forklift pockets on all four sides
Natural Gas Fired
Input Capacity (for every 1000 ft. increase in elevation after 2000 ft, input BTU's are derate by 4%)
1,233,000 BTU/H
Output Capacity (for every 1000 ft. increase in elevation after 2000 ft, input BTU's are derate by 4%)
1,023,390 BTU/H
Gas Pressure Range
6” to 14” W.C.
Consumption - max
1,233 CU.FT/H (34.9 CU.M/H)
Propane Fired
Input Capacity (for every 1000 ft. increase in elevation after 2000 ft, input BTU's are derate by 4%)
1,233,000 BTU/H
Output Capacity (for every 1000 ft. increase in elevation after 2000 ft, input BTU's are derate by 4%)
941,544 BTU/H
Gas Pressure
11” W.C.
Consumption - max
12.4 US GAL/H (46.9 L/H)
Control & Monitoring
Specs
Full gauge panel monitoring circulation fluid temperatures & pressures, fuel pressures
8-light system operation feature for easy system troubleshooting
Module Fluid Circulation System
Basic Features
Atmospherically vented low pressure system, adjustable fluid temperature control, auto pressure by-pass for pump protection and variable flow demands, auto temperature bypass for heat exchanger protection
Heat Transfer Fluid (HTF)
Non-toxic propylene glycol / water mixture, freeze protected
Primary Lines & Couplers
2' fluid circulation lines, 2” ball valves, 2" Kamlock quick-couplers
Circulation Pump
2 HP, 80 GPM (364 LPM) @ 30 P.S.I.