Specifications
General
Temperature Range
120°F to 200°F (49°C to 93°C)
Weight
820 LBS. (372 KG)
Electrical
115 V, single phase, 60 Hz, 15 A
Natural Gas Fired
Input Capacity (No BTU deration for high altitude operation)
248,000 BTU/H
Output Capacity (No BTU deration for high altitude operation)
199,000 BTU/H
Gas Pressure Range
5”-14” W.C.
Consumption - max
248 CU.FT/H (7 CU.M/H)
Propane Fired
Input Capacity (No BTU deration for high altitude operation)
248,000 BTU/H
Output Capacity (No BTU deration for high altitude operation)
199,000 BTU/H
Gas Pressure
11” W.C.
Consumption - max
2.71 US GAL/H (10.3 L/H)
Controls & Monitoring
Specs
Full gauge panel monitoring circulation fluid temperatures & pressures, fuel pressures
8-light system operation feature for easy system troubleshooting
Module Fluid Circulation System
Basic Features
Atmospherically vented low pressure system, adjustable fluid temperature control, auto temperature bypass for heat exchanger protection
Heat Transfer Fluid (HTF)
Non-toxic propylene glycol / water mixture, freeze protected
Lines & Couplers
1” fluid circulation hose, 1“ quickcouplers
Circulation Pump
3/4 HP, 30 GPM (136 LPM) @ 30 P.S.I.