900,000 Btu

900,000 Btu

dryair diesel heater photo

Specifications

General

Burner
Two stage, Diesel fuel/#1 or 2 heating oil, 85% efficient
Weight
Dry - 2,800 LB., 1,270 KG / Wet - 4,100 LB., 1,860 KG
Electrical
Single phase, 115/230 V, 60 Hz, 30 Amps
Loading - Standard
Forklift pockets on all sides

Fuel Specs

Input Capacity
896,000 BTU/H, 260 KW/H
Output Capacity
761,600 BTU/H, 221 KW/H
Fuel Consumption
6.4 US GPH, 24.2 LPH, 20.7 KG/H

Fuel Tank

Type
Welded steel
Fuel Capacity
190 gallon main tank / 80 gallon piggy tank
Operating Range
45 hours

Before System Start-Up

Pre-Heater
4000 Watt electric circulation heater, 230V, preheats heat exchanger glycol before system start-up

During System Start-Up

Fuel Heater
Automatically maintains set fuel temperature; luid (hot glycol)-to-fluid (fuel) heat transfer
Combustion Air Heater
Automatically maintains set combustion air temperature; Fluid (hot glycol)-to-air heat transfer utilizing a heat transfer coil

Control & Monitoring

Specs
Pump & temperature controls; Full gauge panel showing circulation fluid temperatures & pressures, fuel pressures and 8-light system operation feature for easy system troubleshooting

Internal Fluid Circulation System

Basic Features
Atmospherically vented & low pressure, single supply & return, adjustable fluid temperature control, auto pressure bypass for pump protection and variable flow demands, auto temperature bypass for heat exchanger protection
Circulation Pump
RPM - 2900 / 2 HP., 1.5KW / Flow - 80 US GPM @ 30 P.S.I., 16 M³/HR @ 21 M W.C.
Primary Circulation
Fluid circulation lines - 2”, 50 MM / Ball valves - 2”, 50 MM / Kamlock quick couplers - 2", 50 MM
Heat Transfer Fluid (HTF)
Non-toxic propylene glycol / water mixture, freeze protected